The test setup - five fire tests with
varying room sizes and material
distributions

The TIMpuls Full-Scale Compartment Fire Tests

The following research objectives were defined for the final five TIMpuls full-acale compartment fire tests under natural fire conditions:

  • Validation of the results from previous component-scale experiments in a "real test structure" under natural fire conditions:
  • Influence of combustible component surfaces on fire progression
  • Behavior of fire protection cladding and its protection times under natural fire exposure
  • Behavior of wooden structures regarding self-extinguishment and post-fire behavior
  • Extinguishability of standard construction methods in timber construction
  • Analysis of fire spread through the façade to the floor above the fire floor due to combustible surfaces in the room
  • Investigation of the effects of fire protection measures in the joint and connection areas of components
  • Evaluation of structural stability under natural fire exposure
  • Assessment of compartmentation (fire and smoke resistance, thermal insulation) under natural fire exposure
  • Review and final evaluation of the current timber construction guidelines in German building regulations

Setup

T0-T2

T3-T4

Overview of the execution features of the test rooms for tests T0 to T4

Test

T0

T1

T2

T3

T4

Compartment size (inside)
(W x L x H)

4.5 m x 4.5 m x 2.4 m

4.5m x 9.0 m x 2.4 m

Floor space

20.25 m2

40.50 m2

Fire load density

1085 MJ/m3

Wall 1

100 mm CLT
2 x 25 mm GPF

100 mm CLT
18 mm GF

150 mm CLT

140 mm LTF
2 x 12.5 mm GF +
12 mm OSB

150 mm CLT

Wall 2

100 mm CLT

2 x 25 mm GPF

100 mm CLT

18 mm GF

140 mm LTF

2 x 18 mm GF

140 mm LTF

2 x 18 mm GF +

12 mm OSB (half wall)

140 mm LTF

2 x 18 mm GF

Wall 3

100 mm CLT

2 x 25 mm GPF

100 mm CLT

18 mm GF

150 mm CLT

140 mm LTF

2 x 18 mm GF

140 mm LTF

2 x 18 mm GPF

Wall 4

100 mm CLT

2 x 25 mm GPF

100 mm CLT

18 mm GF

140 mm LTF

2 x 18 mm GF

140 mm LTF

2 x 18 mm GF

140 mm LTF

2 x 18 mm GF

Ceiling

180 mm GLT

2 x 25 mm GPF

180 mm GLT

220 mm LTF

2 x 18 mm GF

180 mm GLT

180 mm GLT

Linear components

-

-

-

-

2x Column*

1 x Beam**

Exposed surface (initial)***

-

35 %

37 %

42 %

58 %

CLT = cross-laminated timber
LTF = light timber frame
GLT = glued-laminated timber
GPF = gypsum plasterboard type F
GF = gypsum fiberboard
OSB = oriented strand board

*Column 300 × 300 mm2 GLT
**Beam 300 × 320 mm2 GLT
***As percentage of the total compartment surfaces excluding floor and window